Detailed Product Description:
* AC220V + 9V back-up Battery
* Gas and Co Sensor
* Hush and test Button
* Visual and audible alarm function
Features:
* Excellent reliability & high stability.
* Durable sensor head.
* Self test function
* Visual and audible alarm function
* Low voltage warning
* Sensor-fault detection
* Can be connected with valve
* Less affected by other organic solvent.
* Loud sound signal of 85 dB at alarm mode.
* Three-year limited warranty.
* Low power consumption
* Test button to test the units electronics and verifies proper unit operation.
* Easy installation with a plastic bracket.
* Widely use for home, coal station, colliery, car and so on.
* Detect all sorts of combustible gases, such as coal gas, liquid petroleum gas and natural gas, carbon monoxide and monitor automatically.
Specification:
* Power supply: AC220V/50~60Hz
* Sensor: Electrochemistry Co and Gas
* Static current: ≤40MA
* Alarm current: ≤80MA
* Static consume: lower 0.6 W
* Alarm consume: lower 2W
* Alarm volume: ≥85dB within 1 meter
* Operation Ambient Condition: 4~38°C, 25~85%R.H.
* Alarm density:
Carbon monoxide:
50PPM: 60-90 minutes
100PPM: 10-40 minutes
300PPM: less than 3 minutes
400PPM: Immediately
Coal gas: 1000~5000ppm,
Liquid petroleum gas: 1000~5000ppm,
Natural gas: 1000ppm~5000ppm
*.Responding time: Gas ≤30S
*.Alarm output: frequent on or off signal, control exhaust fan, electrical magnetic valve signal.
EMERGENCY ALARM TREATMENT:
The Detector alarms while the gas density in air exceed the alarm level. The relative treatments as below:
1. Shut down the tube valve right away.
2. Open the window and make the air flow rapidly.
3. Extinguish all fire sources and do not use anything can make fire, e.g. lighters, matches, etc.
4. Avoiding open or close the power all kinds of electric equipment.
5. Check the reason of gas leaking, and notice the relative departments and professional persons in time.
2012 New Hot Sale China Produced Gas Leak Detector with CE Approval